Klipper endstop always triggered.
Basic Information: Printer Model: Voron 2.
Klipper endstop always triggered We choose to not use github to help diagnose problems with a user's printer. Please help me!. 5 MB) Describe your issue: When ever i try to print something it heats up like normal but the just doesnt do anything? i check my fluidd and i try to home all positions but it starts making a buzzing noise and says " !! Endstop Z still triggered after retract"? I don’t know SOLVED: see the additional post I made below I have an skr pico I'm trying to get endstop functionality working on. x is plugged into Diag0 (PG6) and Y into Have a Neptune 4 Max, using z- endstop pin ^PC12 and ground connected to sexbolt I have klacky, always working good. "Endstop y still triggered after retract. On the wiring, I used the 5v Endstop port: 5v to 5v, gnd to gnd, and signal to GPIO28. log klippy2708. open z:open. 6 MB) MCU / Printerboard:Octopus pro V1. What I have tried: Replaced BTT SKR Mini E3 v3. In this case, connect the Smart Effector to # a different pin on the board. Basic Information: Printer Model: V Core 3. Just purchased and set up a Creality Sonic Pad for my CR-6 Max. cfg provided by bigtreetech, and the only issue is regarding the Cr Touch Reporting endstop status x_max: TRIGGERED y_max: TRIGGERED z_max: TRIGGERED when I manually press them they open as below SENDING:M119 Reporting endstop status x_max: TRIGGERED y_max: open z_max: TRIGGERED I guess above setting is alright. To get ONLY the BL Touch working, you need to change the endstop pin = ~PD29 parameter to endstop_pin: probe:z_virtual_endstop to pick up the BL Touch. everything worked with Marlin, I was printing 1 hour before switching to Klipper I used the print. ' And it won't 'home' because it thinks it already IS homed - because the z-min is TRIGGERED. 1 MB) I have setup senseless homing per the guide. 3: 3562: December 18, 2024 I have installed Voron Tap / BTT SB 2240 and completed all cfg files in Mainsail. Klipper3d / klipper Public. I have built a printer which has Z endstop on the bottom and I intend to use it with klipper. Strange enough a normal endstop works fine?! rotation_distance: 8 # Use 4 for Ender5 versions after late 2019 endstop_pin: probe:z_virtual_endstop #position_endstop: 0 position_min: -2 # The Z carriage may need to travel below the Z=0 # homing I switched to Klipper and set the sensor port to ^PC2 (not sure what the ^ means), it reports always triggered during the DEBUG pin_up, pin_down test, even with the BLTouch disconnected from the z-stop. SKR E3 2. 4 and everything is connected with the firmware dual endstop LR. i also perforemd the initial test from klipper Klipper's endstop phase system combines the stepper phase with the endstop trigger to improve the accuracy of the endstop. The probe/needle does not extend or retract and the red light stays ago on the device. Here, enthusiasts, hobbyists, and professionals gather to discuss, troubleshoot, and explore everything related to 3D printing with the Ender 3. I’ve got a rambo 1. Edit 2: Solved it. Once you have that confirmed, release the switch, click on the circling arrows and see if it is noted I believe you need to flip logic of endstops. # If an endstop_pin is defined for the additional stepper then the # stepper will I finally decided to convert my CR-10 over to Klipper. [bltouch] sensor_pin: ^PB1 control_pin: PB0 x_offset: -36 y_offset: 0 z_offset: 0 pin_up_touch_mode_reports_triggered: true However the z_max is always triggered regardless of the manual state of the switch, i. 0 has its signal wire connected to an endstop pin (with a noise filtering Welcome to the Ender 3 community, a specialized subreddit for all users of the Ender 3 3D printer. The sensor is a normal 6-36v inductive sensor with three wires, vsg. So signal and ground, nothing powered from the 3. 6 KB) Update: This was kind of embarrasing, The endstop/probe was working! I dont know why but I kind of expected the indication of status of the endstops to change as they were triggered. UPDATE: I missed your message that you Your X endstop is configured to be at position 20. The light on the PCB board stays red even when it should trigger. h for Z_MIN_ENDSTOP_INVERTING and Z_MIN_PROBE_ENDSTOP_INVERTING from false to true. Probe LED is on and when it is close to the bed it turns off as it should. If the QUERY_PROBE commands in that test always produce the expected results and "BLTouch failed to verify sensor state" errors still occur, then it may be necessary to set pin_up_touch_mode_reports_triggered to False in the "klipper Endstop x still triggered after retract" message. I didnt touch the HW. 0 (due to failed board before / Plausible new board is You signed in with another tab or window. 7. yet no triggering of the y-endstop happening, it is in a constant "open" position, causing my bed to crash into y=0. its only my 2nd day using anything Klipper related. Closed KthulhuFtaghn opened this issue Feb 16, 2021 · 1 comment Closed We choose to use github as a place that people working on improving Klipper can share the results of their work. BLTouch with Klipper and the Ender3 - This was an early follow along tutorial by Tomohulk on gitbub. ) Currently, the only way to do this reliably is if both the It won't 'home. Klippylog attached. # If an endstop_pin is defined for the additional stepper then the # stepper will Z-endstop still triggered after retract . This can result in random triggering or in your case the endstop triggered all the time. You switched accounts on another tab or window. i dont know if thats relevant. (If the two are always reset together then Klipper can determine the stepper phase by tracking the total number of steps it has commanded the stepper to move. sensorless homing on x and y . Try moving the toolhead to several different /r/klippers -- a place to discuss all things related to the Klipper 3d Printer Firmware. This is the same for both x and y endstops. From Mainsail I can see that Endstop Z and Probe always Triggered. And if you do touch it, be very gentle, in order to not bend or push anything. If you have a [safe_z_home] section, you need to comment out the entire block (not just the [safe_z_home] line!). It is most useful when using a Trinamic stepper motor driver that has run-time configuration. And with triggering z axes probe it didnt make homing This document describes the commands that Klipper supports. Along with specifying the endstop_pin probe, change your sensor_pin = PC1 parameter in the BL Touch statement to sensor_pin = ^PC1 to enable the internal pull up in the MCU as the BL Touch pin BL Touch - Klipper Documentation (Won’t let me use the link, but it’s the official Klipper doc). x end stop is definitely recognized by klipper - if I end stop is closed x is moving right during homing, otherwise x is moving left during homing. Still same issue. After setting up Y was fine but X was always triggered. log Describe your issue: klippy. log (25. I flashed two different builds of Klipper on it, and the X and Y endstops always return either TRIGGERED or not I confirmed with QUERY_ENDSTOPS that it is always triggered, even when I unplugged the connector. log f As you can see, it is configured as "pin: !ar18". Locate the y-axis Endstop, which is the switch located to the right of the rear stepper motor; open z:TRIGGERED; You can repeat this step for both left and right z-axis Endstops; Remove the object(s) from the z-axis sensor(s); Yeah, it’s called out but Reddit murdered the formatting. So here's the problem: The z-min is NOT triggered. When I got to the part of the guide regarding bltouch I began For Klipper I had to set the probe Pin to be the z_endstop pin which is PC0. When I issue a G28 at the console, it works exactly as one would expect on a CoreXY machine -- home X, home Y, home Z. multimetered the wiring, the endstop switch and all works fine. My hardware is Raspberry 3B+, Arduino Mega and RAMPS 1. 3 Host / SBC: Orange Pi klippy. I take the Ok after I commented the overlapping lines now it errors out with endstop z still triggered after retract TheTik • 11mo ago Okay, same thing for non-toolboard [probe] section When I try to auto-home or manually move the z axis offset, it only moves up, not down at all. I've gone over the code about a million times I have the same issue on my Anycubic Kobra Max w/ Trigorilla Pro 1. Note, if this is used in a macro, due to the order of template expansion, the QUERY_ENDSTOP Klipper's endstop phase system combines the stepper phase with the endstop trigger to improve the accuracy of the endstop. General Discussion. Basic Information: Zero G Mercury Ender 5 Plus Voron stealthburner and TAP Manta m8p v2 Mantam8pEnder5plusconfig. comment for mannual mesh bed leveling #endstop_pin = probe:z_virtual_endstop ## comment 2 lines below for 3dtouch bed leveling and to disable Z Basic Information: Printer Model: Voron 2. 0. After performing the above, the Same issue here, sensor seems dead :( , started to face @Bexman issues randomly at the beginning. I take senzor wires and (Black and white /gnd and signal) use Z_min endstop to make it work. I accidentally ordered a PNP probe so I made it go to an NPN transistor with a pullup resistor on the input and it seemed to work. If you connected a 2-pin endstop to + and GND instead of Sig and GND, it will create a short every time the endstop is pressed, in which case the board turning off is the best case scenario. After performing the above, the Setting up Klipper with a SKR Mini e3 v2 and a BLTouch clone. zip Can someone check out my cfg and log file, Trying to set up sensorless homing and have searched the forums for the last 3 days. endstop_pin: probe:z_virtual_endstop #position_endstop: 0. A warning before you start: Avoid touching the BL-Touch pin with your bare fingers, since it is quite sensitive to finger grease. 4 KB) Hello, I’m working on adding the KevinAkaSam Klackender probe (klicky probe) to my printer but it is reporting that the probe is permanently triggered preventing any homing. Check this out from the klipper documentation, I made the same goof "If the BL-Touch will be used to home the Z axis then set endstop_pin: probe:z_virtual_endstop and remove position_endstop in the [stepper_z] config section, then add a [safe_z_home] config section to raise the z axis, home the xy axes, move to the center of the bed, and home the z axis. Config. Is there another settings somewhere that I need to adjust? When I run ‘query_endstops’ it Last week I was trying to set up senseless homing because I accidentally broke an end stop. (And I am not lying when I say it's not the only thing that's f*ing triggered at this point. I have a 3DTOUCH probe as well. ) Currently, the only way to do this reliably is if both the Klipper supports the following standard G-Code commands: Move (G0 or G1): G1 [X<pos>] [Y<pos>] M109 always waits for temperature to settle at requested value; Set bed temperature: M140 If STOP_ON_ENDSTOP=1 is specified then the move will end early should the endstop report as triggered (use STOP_ON_ENDSTOP=2 to complete the move without Endstop z still triggered after retract Btw, I use a BTT EBB Can 36, I already changed the wires, tried connecting it to the motherboard instead of the can. gcode. x. 8k. Endstop phase¶ This document describes Klipper's stepper phase adjusted endstop system. Setting this to something # other than 0 will cause occasional erroneous results. 8 MB) Describe your issue: I am working on running my printer and having trouble with the Z-axis. Klipper is a fantastic way to go, but it can be a real PITA to get right Everything works except Z Endstop and Probe are always triggered. 2 board died) MCU: Leviathan v1. Re: Z_MAX always triggered December 06, 2014 07:30PM This section explains how to verify that all of the Endstops are detected by Klipper. 5: 6587: August 9, 2023 Home ; Categories ; Final setup . Setting the two "always triggered" steppers to 2 amps was an act of desparation. 5: 852: Endstop y still triggered after retract - Ender3 V2 with BLTouch. Note, due to the order of template expansion (see above), the QUERY_STATUS command must be run prior to the macro containing this reference. KangaGorillaPig. M109 always waits for temperature to settle at requested value; Set bed If STOP_ON_ENDSTOP=1 is specified then the move will end early should the endstop report as triggered (use STOP_ON_ENDSTOP=2 to Endstop z still triggered after retract. 3 KB) I can’t get the endstop switches to trigger. 0 Klipper state: Ready G28 Endstop y still triggered after retract what wong. A typical endstop switch has an accuracy of around 100 microns. Finally gave up and moved the black/white wire to the 4/5th pins of the PROBE header, and set the sensor port to PC14. At first, I suspected that maybe there was Tried, same results. 7 main board that i had in it previous. When I attempt a G28, the process fails with Endstop z still triggered after restart. Attached is the log after doing a test-bltouch. I have tried both the pin_up_touch_mode_reports_triggered: True/False && pin_up_reports_not_triggered: True/False. if I manually depress the switch and issue M119 the result do not change. No matter what configuration I use, or pin on the board, the BLTouch is always in a triggered state. Roland September 24, 2024, Endstop z still triggered after retract. The probe is a limit switch with two wires that go to ground I recently updated klipper version to 12. In my case, the extruder fan was always running at 100% and the parts fan started when the hotend was over 50°, so I commented out all the line [heather_fan hotend] and activated the fan Hi i’m new here from the Netherlands. The z-min is free and clear open. Check Klipper out on discord, discourse, or Klipper3d. In mainsail under “Endstops” Endstop x still triggered after retract” message reporting as well. I am attempting my first print, but I get the following error, "Endstop z still triggered after retract" I am a complete novice when it comes to 3D printing. it's a sensorless homing setup and I have jumpers over both the x and y diag pins Great Prints? Klipper can help you and your machine produce beautiful prints at a fraction of the time. 2 board on and Ender 5 Pro. When I take Hi, i'm an EN3MAX owner as well, and tried klipper for the first time, i had problems with de Z axis, when i try return to home at the original firmware, the printer gets stuck when trying to reach the hotbed, (it never gets down) so this is why i decided to give up with elegoo firmware and installed klipper, but now i'm stuck with the Printer. Basic Information: EZABL PRO with SKR 2. THE SWITCH ISN'T EVEN PLUGGED INTO THE BOARD FOR FECK'S SAKE. When I try doing the fingernail test and query the probe it also never responds "triggered", and always responds with "open" My Config *I changed my Z_Endstop to "z_virtual_probe, dunno if that may be the source of the problem but just making that clear: Klipper’s endstop phase system combines the stepper phase with the endstop trigger to improve the accuracy of the endstop. I’ve tried to unplug everything and plug a endstop in to it but is still says triggered. ) atmega 1284p melzi sanguino ender 2 z endstop always triggered #3941. • Especially for testing purposes and to make sure not to damage the printer reduce homing_speed = 200. 65 y_offset: -10 z_offset: 0. I am currently running into an issue with the Z axis probe which is an EZABL. But sometimes this option is necessary in complex mechanisms, for example, the toolchanger mechanism. y and z both work fine as expected. EZABL PRO with SKR 2. The results are actually: SENDING:M119 Reporting endstop status x_min: open y_min: open z_min: I haven't been successful in using btt eddy as an endstop, so I'm going to the mechanical z endstop. System Information. org Endstop z still triggered after retract Then RESTART the printer and run a G28 command followed by an ENDSTOP_PHASE_CALIBRATE command. I don’t know much about Gcod, yet! 3-pin endstop connector on board. It’s wired in for an SKR 1. _1. I can not for the life of me get the Z endstop to trigger with the lifting up of the stealthburner. last_query["<endstop>"]: Returns True if the given endstop was reported as "triggered" during the last QUERY_ENDSTOP command. . 1: 1481: June 22, 2021 Ender 6 ezabl pro. 3 firmware built from the update. 0 has its signal wire connected to an endstop pin (with a noise filtering Printer: Ender3pro Firmware: custom marlin 2. ^PA6 (y-endstop) always shows open. cfg. I had a problem today where the endstop was triggered when the endstop wasn't triggered: the switch was open, my meter said the switch was open, but klipper said it was triggered. but the problem is when i press the home button x and y axis moves around 1cm each Basic Information: Printer Model: Ender 3 Pro MCU / Printerboard: BTT SKR E3 V2 Host / SBC klippy. query_endstops. Note TMC2209 keep DIAG signal low and raise up for short period of time when stallguard detected so you should never see them in TRIGGERED state. Whenever I go home all axis, it says the Z end-stop is constantly triggered. Slide the probe to the middle of the bed. ) config. 1 Host / SBC klippy. I get the endstop popup menu to allow for endstop check. Then move the toolhead to a new location and run G28 again. My first issue is the Z_MIN setting is always TRIGGERED when I run a m119 command. x Z endstop: BLTouch 3. Close Hello, I'm upgrading my 2. I’ve got a lowrider 2. e. But my printer is working before this. I believe I have it configured Trying to setup my BDsensorM v1. I’m running UART and the DIAG jumpers are on M0 and M1, but no matter what I set my stall guard to it just won’t move. Klipper version: master; Stepper motors: 1. z-endstop isn’t needed due to virtual_z_ednstop of the BLTouch. If the endstop appears inverted (it reports "open" when triggered and vice-versa) then add a "!" to the pin definition (for example, "endstop_pin: I've just now encountered this problem after months of perfect functionality. any help would be greatly appreciated Then RESTART the printer and run a G28 command followed by an ENDSTOP_PHASE_CALIBRATE command. A couple questions: I have a new motherboard I am trying to get working. The problem is that I cant use home because the endstops is not triggerd. This gives you time to react Then RESTART the printer and run a G28 command followed by an ENDSTOP_PHASE_CALIBRATE command. Where in Klipper do I indicate the x y location of the probe? When I read the Voron documentation, it seems like it ought to be BLtouch worked fine on Marlin but shows always triggered on Klipper. 4 MB) So this keep is happening. You signed out in another tab or window. 4 to tap and the z-endstop isn't being recognized in klipper. 0 z_endstop always triggered. I can successfully send pin up and pin down without issue. The idea is to provide a configuration to define a “virtual” endstop by a state of an ADC pin (crossing some threshold value). I can manually push the pin up or use a command to move it up, it registers open. Now it reports always open. Hook up the BL-Touch “servo” connector to a control_pin according to the BL-Touch documentation or your MCU documentation. 4 and have tap installed using an OptoTap PCB OPB sensor and Hartk1213 5-24v stealthburner pcb. After performing the above, the This document describes the commands that Klipper supports. The following information is available in the configfile object (this object is always available):. 1 Main board: BTT SKR Mini E3 V1. 0. You have to include its a bit to learn. 1) General Discussion. # If an endstop_pin is defined for the additional stepper then the # stepper will How its connected to your board? I had the same problem when BL Touch was pluged into dedicated 5 pin connector on Creality 4. Always run G28 first and then run SCREWS . 0 to 100 or even 50. M119 reports X_MAX_ENDSTOP is triggered all the time (even when switch is manually closed) but when I invert it (X_MAX_ENDSTOP_INVERTING -> true), the printhead moves in the correct direction during auto-homing, but keeps crashing into the frame. log Hello again! klippy (5). I’ve swapped out the end stops with others i had and still the same, I’ve check the cables are plugged into the correct ports in the board and i can not figure out why this is happening. I am just confused as to why it drops and then stows immediately when trying to probe the bed. Try moving the toolhead to several different locations and rerun G28 from each position. 4. Run at least five G28 commands. the weird part is that changing the config for the x-endstop to be on ^PA6 (y-endstop pin) and manually triggering ^PA5 (usual x-endstop pin), the x-endstop shows to trigger/open. z motors dont move klippy(10). 1 Klipper shows probe as always triggered , no matter is it near bed or in mid-air. log (4. Initially I was getting the “end stop triggered Okay, thanks, I’ll give it a try. # If an endstop_pin is defined for the additional stepper then the # stepper will Basic Information: Printer Model: Modified Ender 3 MCU / Printerboard: Manta E3EZ + EBB SB2209 klippy. I am using the latest Marlin-bugfix-2. I do get the red light when relaxed and the blue light once lifted. I also cannot get the Part Cooling I'm running stealthburner with CW2 on my 2. 0 Host / SBC Rasberry pi 4b klippy. G1 X0 Y0 Z10 F4000 ##### Start Print and End Print Klipper uses the hardware names for these pins Some boards have a low # value pullup resistor on the Z probe input, which will likely result in an # always-triggered probe state. ) Currently, the only way to do this reliably is if both The z endstop is always shown triggered when queried in mainsail m119. I have 3 pins connected to the bltouch connector and 2 in the Z endstop. After putting something metal right up against the probe I get “triggered”. log (1. Querying endstop status stow and deployed returned always TRIGGERED status and not able to do homing any more, changed to SuperPinda to fix my issues as currently no replacements showed on BIQU Store. Or you could just delete the entire block, but if sensorless homing doesn’t work reliably for you for some reason and you decide you want to go back to a physical endstop setup, you’ll be glad you didn’t delete it. 675 stow_on_each_sample: False probe_with_touch_mode: True pin_up_touch_mode_reports_triggered: False x_offset: -43. I installed an inductive sensor on my skr 1. zip. ) Currently, the only way to do this reliably is if both the endstops_enable true # The endstop module is enabled by default and can be disabled here #corexy_homing false # Set to true if homing on a hbot or corexy BLTouch is always triggered July 18, 2017 12:20PM Registered: 8 years ago Posts: 759 not tooo familiar with smoothiwar but it looks like you dont have a pin assigned to the 'gamma min The endstop oversampling was implemented to address noise in endstop signals on older machines (approximately 7 years ago), and may be better suited as an optional feature. 4 KB) klippy (2). Closed CopterFail opened this issue Aug 22, 2019 · 4 comments When I set a new pin for the end stop, I can toggle the endstop on and off by shorting the s pin to the ground. Thas my klipper config part for probe: [BDsensor] sda_pin: PE10 scl_pin: PE9 de Klipper uses the hardware names for these pins Some boards have a low # value pullup resistor on the Z probe input, which will likely result in an # always-triggered probe state. 2 Tool Head: NiteHawk SB Controller: Raspberry Pi 3B+ Endstop With my CL CNC Tap, the light will be bright red when open, and only slightly dimmer when triggered, it doesn't go completely off. It does not change I have a problem with my y endstop always showing triggered. i also perforemd the initial test from klipper endstop_pin: ^PA1 #endstop configured NC endstop_pin: ^!PA1 #endstop configured NO. If the BL-Touch v3. These are commands that one may enter into the OctoPrint terminal tab. For the fan, I have the beginnings of a solution. 4 MCU / Printerboard: BTT Octopus V1. Strange thing though; when testing my endstops (very simple switches), connected to PB10 and PE12 (the assigned pins on SKR Pro v1. 2: 426: Klipper Endstop z still triggered after retract. # If an endstop_pin is defined for the additional stepper then the # stepper will Even when restarting klipper. Klipper uses the hardware names for these pins Some boards have a low # value pullup resistor on the Z probe input, which will likely result in an # always-triggered probe state. x). So I checked the pins, i put the Ferrite coil on the end stops to kill noise. Just plug your probe into the Z endstop connector instead, you can get the pin number from the stepper_z definition (I believe it is I. Klipper I just run the home command again and it almost always works on the 2nd try. log thanks Hi, I have a Tronxy X5SA pro I’m converting to Klipper. The QUERY_ENDSTOPS command should report the endstop as "TRIGGERED". BIQU Microprobe V2 Endstop z still triggered after retract. I did read a LOT of other people having this issue, and always was related to using the wrong pin number. My probe did function 1 week ago. I have also moved the pins to the Z-endstop port and changed the config with the same results. The Switchwire has the x endstop on the carriage, and homes by moving towards x max , to the right, So position of the x endstop will be the same as your max x size. 3 and TMC2209 and normally (always) M119 shows X and Y endstops status as open. 5 [probe] Hold down the switch, click on the circling arrows to do another read, and see if it is recognized as being TRIGGERED. 27) the problem can’t be the board then as ^PA5 (x-endstop) works. From what I understand, homing command wants printer bed to come close to the nozzle and set some value (close to 0) when endstop is hit. Oblikfan October 29, 2024, 12:53pm 1. I did everything in the documentation. checked the connections on the motherboard, everything sitting secure. 2 board, always triggered or open. <option>: Returns the given raw config file setting as read by Klipper during “Probe virtual endstop only as endstop pin” Voron trident Board Octopus Pro. They don’t, you have to refresh the page printer. Klipper Z-Calibration on github refers to this youtube video: For me to follow that video, I need to get klicky probe working. Pinda probe on z x reports “Endstop x still triggered after retract” issue G28 command for z and also get Endstop x still triggered after retract. log (2. Everything has been running great for months. log Fill out above information and in all cases attach your klippy. This should fix it a bit. Thanks . I don’t have a z end-stop. 1. EddyMI3D September 24, 2024, 8:16am 4. 0 mm in my case). Interestingly, I'm facing the same problem but with the Reality v4. Klipper Voron trident tap config. 4 and when I home the printer the led indicates but the printer continues to move the z axis. 2 32bit Problem: Z endstop is always triggered. 1: 1473: June 22, 2021 BIQU Microprobe V2 Endstop z The original system is not able to process endstop sensors as separate objects, like [extruder] or [fan]. 1: 1481: June 22, 2021 Endstop z still triggered after retract on SKR Mini E3 v3. 2: 195: May 27, 2024 Endstop z still triggered after retract? Now you’ve got me rethinking my own homing, but before we get that far. 1 MB) printer-cfg . # If moving from marlin to klipper uncomment to mimic G29 gcode: BED_MESH_CALIBRATE. This functionality can improve the accuracy of traditional endstop switches. <section>. I Klipper uses the hardware names for these pins Some boards have a low # value pullup resistor on the Z probe input, which will likely result in an # always-triggered probe state. 0 Host / SBC Raspberry Pi 3b+ klippy. I have a Beacon3d sensor configured as the virtual endstop. - Set pin_up_reports_not_triggered ? Tried, same results. txt (7. 4 turbo board, Fluiddpi is installed on the pi and I have successful coms. " The probe is stuck on the Y trigger. Of course you can use [gcode_button] for some critical moments, but this klipper object don However, it's recommended to perform Z endstop positioning in software with Klipper - once the physical location of the endstop is in a convenient location, one can make any further adjustments by running Z_ENDSTOP_CALIBRATE or by manually updating the Z position_endstop in the configuration file. " If the QUERY_PROBE commands in that test always produce the expected results and "BLTouch failed to verify sensor state" errors still occur, then it may be necessary to set pin_up_touch_mode_reports_triggered to False in the Klipper config file. (I added pin_up_touch_mode_reports_triggered: False) During homing z, when the pin is triggered (pushed up), it will immediately deploy /r/klippers -- a place to discuss all things related to the Klipper 3d Printer Firmware. I made the required config changes regarding the servo that lifts the What you could try is shortening the two pins of your endstop connector on the board directly (DuPont cable, screwdriver whatever) and see if Klipper reacts. If the QUERY_PROBE commands in that test always produce the expected results and "BLTouch failed to verify sensor state" errors still occur, then it may be necessary to set pin_up_touch_mode_reports_triggered to False in the Klipper config file. Because when I configure it the correct way, the result of "QUERY_ENDSTOPS" is always "TRIGGERED", no matter if the LED on top indicates proximity or not. I have rewired the switch and matched it to the working x axis but it still shows triggered. i also perforemd the initial test from klipper Check Klipper out on discord, discourse, or Klipper3d. Basic Information: Printer Model: DIY cartesian MCU / Printerboard: SKR 1. I've got around it by connecting the switch to a spare pair of pins, but then I had the same problem with the probe, which I got around in the same way, but I don't BLtouch worked fine on Marlin but shows always triggered on Klipper. If I set deactivate_on_each_sample to true, get these errors less often, but the accuracy is worse, and that would also make creating a mesh much slower (the official manual sets it to [stepper_z] endstop_pin: probe:z_virtual_endstop # Configure z homing to use beacon as a virtual endstop homing_retract_dist: 0 # Beacon does not require a homing retract. 0 # Distance to backoff (in mm) before homing a second time during # homing. 4k; Star 9. klippy. zip (155. The following information is available in the query_endstops object (this object is available if any endstop is defined): last_query["<endstop>"]: Returns True if the given endstop was reported as "triggered" during the last QUERY_ENDSTOP command. I figured I would give Klipper a try to further optimize my prints. It works, they trigger when they The following information is available in the query_endstops object (this object is available if any endstop is defined): last_query["<endstop>"]: Returns True if the given endstop was reported as "triggered" during the last QUERY_ENDSTOP command. Klipper BIQU Microprobe V2 Endstop z still triggered after retract. I am not sure if my hw is wrong, but it shouldn't have any BLtouch worked fine on Marlin but shows always triggered on Klipper. When I poll the probe with “QUERY_PROBE” I get “open”. This is not an official Klipper support channel and poorly moderated so ymmv. Then RESTART the printer and run a G28 command followed by an ENDSTOP_PHASE_CALIBRATE command. My Y axis endstop always reads as triggered. I added !PC0 to the probe pin and boom it worked. I recently had to change my probe to a high temp one because my old one wasn’t rated at pc temps. But now it says with M119, triggered. I checked with a multimeter and the switch and the wire going to the board is working. txt (12. 0 has its signal wire connected to an endstop pin (with a noise filtering I’m using Klipper on a printer that will be damaged if an axis is overrun. It works the same as OG Tap, with no other changes. BL touch is working fine BLtouch performs self test, reacts fine to commands like BLTOUCH_DEBUG COMMAND=pin_down and BLTOUCH_DEBUG COMMAND=pin_up but always shows triggered. If I swap the signal and ground from what they should be, the light will toggle when trigger, but klipper doesn't register it when using query_endstops. Try the G28 slides over to the Y acces and the probe hits the Y trigger twice again stays Basic Information: Printer Model: Neptune 4 MAX MCU / Printerboard: ? Host / SBC: ? klippy. Unfortunately the QUERY_PROBE command always returns open. 4 Everything seems to be working fine, just my bl-touch reports always triggered. just use query_endstops and flip the pin in the config of you need to. Reddit - Klipper + Ender 3 v4. 3V. log Describe your issue: Have installed skr mini E3 V3 MCU in my ender 6. 4 A. (Any settings changed at run-time will not be reflected here. log I’m going to finish my BLV Cube, but I have a strange problem with my Klipper configuration: when I try to move the motors, they emit a whistling sound but don’t move. org "Endstop x still triggered after retract" weirdness All, I have this problem, and it is vexing me. klippy(1). to be the same G28. I would like to stop a print if an endstop is triggered after homing due to missed steps, poor configuration, etc. 1 500 MCU / Printerboard: Octopus Pro klippy. Refuses any other commands at this point. For giggles, my delta has simple switches as endstops and are configured as: endstop_pin: ^!ar2 endstop_pin: ^!ar15 endstop_pin: ^!ar19 — You are receiving this because I was able to get printer connected but when I try to home all, I get an error message saying “Endstop z still triggered after retract”. Reply Quote. Only when doing it as above, it differentiates between "OPEN" and "TRIGGERED", but it's showing the opposite value. İt works at first but now it behave strange. 4 KB) klippy. Anyone know what could be issue? What else could be triggering Z_MIN? If the QUERY_PROBE commands in that test always produce the expected results and "BLTouch failed to verify sensor state" errors still occur, then it may be necessary to set pin_up_touch_mode_reports_triggered to False in the Klipper config file. I have tried to configure x-endstop on my Tevo Black Widow 2130 customized printer. 3 KB) But the new probe seems to be always in open state so homing Z doesn't work. 2 board + 3D Touch clone and Reddit - BLTouch reports as triggered. Of course, using The Z axis lowers a litttle bit but does not deploy the BL Touch and then stops and gives the klipper error ‘Endstop z still triggered after retract’ . I think some boards respond differently, the above is straight from my skr2 config, I'm sure somewhere all of my endstops are inverted despite using the same physical switches. Ender 3 v2 using octoprint and klipper. In my case, I would like bed to get away from nozzle and set value to Z-max (200. didn't change a thing. settings. White Wire from BLtouch is plugged into Z-Stop (PC2). Reload to refresh your session. I also updated the SKR1. Able to manipulate the probe without issues. I have working sensorless configuration with SKR 1. Basic Information: Printer Model: Voron 2. It is a MKS SGEN_L V2. /r/klippers -- a place to discuss all things related to the Klipper 3d Printer Firmware. Attachments. # If an endstop_pin is defined for the additional stepper then the # stepper will I also have a BLTouch ( had it for ages ) and it worked under Klipper and on the v. 4 klippy (5). If you're not seeing the endstop status change it would generally indicate an incorrect wiring or configuration of the diag pin, and/or Hi, I have been printing using marlin for a couple of months now with no major issues. I’m sure there is a way to designate the SERVO pin to be used as the z_virtual_endstop but the standard way below does not work. Upon sending QUERY_ENDSTOPS with and without triggering SKR E3 2. 98 speed: 20 lift_speed: 20 samples: 1 Basic Information: Printer Model: BLV CUBE MCU / Printerboard:RADDS with ArduinoDue Host / SBC klippy. 7 mb + cr touch Ive setup my raspberry pi with fluiddpi, got it all connected locally and im now having what seems to be the common problem of configs Klipper is not recognizing my probe, always open or always closed by switching the logic back. And i am mostly using the ender 3 v2 printer. 0 board with MKS TMC2208 drivers in UART mode. You don’t have these options setup in your steppers for homing: #homing_retract_dist: 5. But when I try to home that axis, the state turns to triggered and stays triggered till I do a hard reboot. i swapped the connectors around and it then shows x is triggered. Here’s an example of what I’m using right now: [adc_endstop probe] pin: PC2 threshold: 0. M109 always waits for temperature to settle at requested value; Set bed If STOP_ON_ENDSTOP=1 is specified then the move will end early should the endstop report as triggered (use STOP_ON_ENDSTOP=2 to Basic Information: Printer Model: Creality Ender 6 E3D Hemera extruder MCU / Printerboard: Bigtreetech skr mini E3 V3. Any help would be appreciated. they are the same switch so am lost as to what the problem is I've attached my config file. <option>: Returns the given config file setting (or default value) during the last software start or restart. They are working, an led lights up when the switch in closed and the sense pin goes to 5v, but the sense pin is at 3v when switch is open. 0 has its signal wire connected to an endstop pin (with a noise filtering Hi there, first post since I’m trying to switch from RepRap/DWC to Klipper/Fluidd! Loving it so far, can’t wait to start printing with input shaping. Klipper Endstop Switch Crash Protection. When ı want to home all axes it home first x and y (normally) but then the z axis sensor being triggered. My Z endstop/probe for If the endstop appears inverted (it reports "open" when triggered and vice-versa) then add a "!" to the pin definition (for example, "endstop_pin: ^!ar3"), or remove the "!" if there is already one present. Question: How does Klipper behave on temporary disturbance (triggered by EMF, cable, LED light) of an ENDSWITCH? Is the stepper stopped but the internal position updated, resulted in a layer shift (permanent for this print)? ENDSTOP trigger during print #1903. 14 [probe] pin: Klipper uses the hardware names for these pins Some boards have a low # value pullup resistor on the Z probe input, which will likely result in an # always-triggered probe state. Connecting BL-Touch. That can't be accurate - you'd be unable to move < 20 if there was an endstop there. 23 KB · Problem: X and Y endstops show triggered regardless of configuration and pin settings Equipment: Printer: Trident 300 (Note this was a working printer with over 1500 hours on it before the Spider 1. when I do a QUERY_ENDSTOPS, the x endstop always shows up as TRIGGERED no matter what. My [probe] config section also has the pull-up : pin: sb2040:gpio28. 25. 7: 134: October 29, 2024 Sensorless homing always triggers (TMC2209 BTT Octopus 1. please bare with me. Im using an ender 3 neo. cfg cuz i'm not and expert on 3Dprinters Welcome to the Ender 3 community, a specialized subreddit for all users of the Ender 3 3D printer. log (73. 8 degree LDO-42STH48-2504AC; Stepper drivers: TMC2209 (also reproduced with TMC5160) Microstepping: 64 Klipper's endstop phase system combines the stepper phase with the endstop trigger to improve the accuracy of the endstop. Running QUERY_PROBE always says "triggered", whether the probe has been deployed or not. Notifications You must be signed in to change notification settings; Fork 5. [stepper_z] step_pin: PE2 dir_pin: PE3 enable_pin: !PE0 microsteps: 16 rotation_distance: 8 ## uncomment below for 3dtouch. Hi everyone! I’ve been working on this for my own usage in my spare time, curious if there’s any interest for this feature in the community. I have installed Mainsail on the Pi, compiled the firmware and flashed the printer. log (16. If the endstop appears inverted (it reports "open" when triggered and vice-versa) then add a "!" to the pin definition (for example, "endstop_pin: That probe connector (I think) only works for BL touch, I got this exact same behaviour (endstop triggering) and took me all night to debug. When I try and home the machine, it will jam itself into the frame and just skip steps over and over, this is due to the endstops not trigggering. When sending M119 I get "z_min : TRIGGERED" even if I invert endstop values in configuration. Old Printer? Cheap Printer? New Printer? Bad Prints? Great Prints? Klipper can help you and your machine produce beautiful prints at a fraction of the time. 1 using EXP1 connection on BTT Octopus v1. Note, if this is used in a macro, due to the order of template expansion, the QUERY_ENDSTOP If the QUERY_PROBE commands in that test always produce the expected results and "BLTouch failed to verify sensor state" errors still occur, then it may be necessary to set pin_up_touch_mode_reports_triggered to False in the Klipper config file. SOLUTION: I had the black and white probe pins plugged into the port labeled Trying out Klipper for the first time. 2. I tried changing the order of wires, but nothing works until I tried with the Z-axis, After reading much pro-klipper raving, I decided to update my setup and try it out My current setup is a Ender 3, 4. xce zdufq kgsdj lambr hzifc qexoq ljciu uudfcc gewnst ttcei